- Manual Calorimeter, IKA
- 소형 칼로리메타, C 200

■ IKA
● 가장 경제적인 모델로 열량측정에 꼭 필요한 기능 위주로 구성
● Manual type으로 내부온도조절을 위한 Water 및 Sample의 연소가 이루어지는 Decomposition Vessel에 대한 산소 충진등은 수동임
● Sample 연소는 강한 전기에 의한 자동연소로 이루어짐
● Feeding Air는 99.98% O2 (30 bar Filling Pressure)
● Isoperibol, Dynamic, Time-controlled Method 세가지 방법 선택 가능
- Isoperibol : According to the standard (열량을 측정하는 방법)
- Dynamic : Time reduced isoperibol measurement (기준치 열량에 적합성을 따질때 주로 사용함)
- Time-controlled Method : Measurement time is set to 14 min
● Easy handling via Keyboard and Display
● Software Languages : English / German / Chinese
● Protectio n Class Acc. to DIN EN 60529-IP21
● Analysis of 1g Benzoic Acid NBS 39i-0.1% RSD (Workingset for Calibrations)
● CalWin C6040 Software를 이용 PC와 연결가능 (Option)
● C200 : C200 Calorimeter, Power Pack and Ignition Adaptor, C5010 Decomposition Vessel, C248 Oxygen Station
● C200 halogen : C200 Calorimeter, Power Pack and Ignition Adaptor, C5012 Decomposition Vessel Halogen Resistant C200, 2 Conversion Kit, C248 Oxygen Station
● Decomposition Vessel
- C5010 : Stainless Steel
- C5012 : Stainless Steel with Halogen resistant material with Catalytic Liner
- Combustible Crusible (C14), Crusible Holder (C5010.4) 필요 (Option)
● Manual type으로 내부온도조절을 위한 Water 및 Sample의 연소가 이루어지는 Decomposition Vessel에 대한 산소 충진등은 수동임
● Sample 연소는 강한 전기에 의한 자동연소로 이루어짐
● Feeding Air는 99.98% O2 (30 bar Filling Pressure)
● Isoperibol, Dynamic, Time-controlled Method 세가지 방법 선택 가능
- Isoperibol : According to the standard (열량을 측정하는 방법)
- Dynamic : Time reduced isoperibol measurement (기준치 열량에 적합성을 따질때 주로 사용함)
- Time-controlled Method : Measurement time is set to 14 min
● Easy handling via Keyboard and Display
● Software Languages : English / German / Chinese
● Protectio n Class Acc. to DIN EN 60529-IP21
● Analysis of 1g Benzoic Acid NBS 39i-0.1% RSD (Workingset for Calibrations)
● CalWin C6040 Software를 이용 PC와 연결가능 (Option)
● C200 : C200 Calorimeter, Power Pack and Ignition Adaptor, C5010 Decomposition Vessel, C248 Oxygen Station
● C200 halogen : C200 Calorimeter, Power Pack and Ignition Adaptor, C5012 Decomposition Vessel Halogen Resistant C200, 2 Conversion Kit, C248 Oxygen Station
● Decomposition Vessel
- C5010 : Stainless Steel
- C5012 : Stainless Steel with Halogen resistant material with Catalytic Liner
- Combustible Crusible (C14), Crusible Holder (C5010.4) 필요 (Option)
-
Cat. No Model Type C30-05-005 8802500 C 200 C30-05-008 8803700 C 200 halogen Cat. No C30-05-005 C30-05-008 Type C 200 C 200 halogen Power Input Max. 120 W Power ON-time Continuous Operation Permissible Ambient Temperature 20 ~ 25℃ (Constant) Permissible Humidity 80% Size w400×d400×h400 mm Weight 21 kg Working Range Max. 40,000 J Reproducibility 0.1% RSD (1 g Benzoic Acid NBS39i) Measuring Mode /
Measuring TimeIsoperibol / up to 17 min / Dynamic : up to 8 min
Manual (Isoperibol) : up to17 min / Time-controlled : up to 14 minOperating Oxygen Pressure 30 bar Spare & Optional Accessory
Cat. No Model Type Description C30-05-612 7114000 C5010 Decomposition Vessel, Standard C30-05-616 7215000 C5012 Decomposition Vessel, Halogen Resistant C30-05-618 4028800 C200.2 Conversion Kit for C5012 C30-05-508 3548900 C200.1 Measuring Cup, 2 L C30-05-696 7224500 C14 Combustion Crucible (100/pk) C30-05-620 3016900 C5010.4 Attachment for Combustible Crucible C14 C30-05-632 7198000 C5030 Venting Station (Gas Washing) C30-05-504 3520000 C248 Oxygen Station