- Bioreactor Components
- 바이오리액터 구성품

■ 2, 3, 5, 7, 15L Size의 다양한 Bioreactor Components
■ Chemglass
-
Unjacketed glass bioreactor vessel
Cat. No Model Capacity(L) Vessel Min. working volume (L) Vessel I.D (mm) Overall Height (mm) R12-132-010 CLS-1379-01 2 0.5 105 246 R12-132-013 CLS-1380-01 3 0.5 130 260 R12-132-016 CLS-1382-01 5 1.0 160 260 R12-132-019 CLS-1383-01 7 2 160 360 R12-132-022 CLS-1385-01 15 2.5 222 456 Unjacketed glass bioreactor Red stained
Cat. No Model Capacity(L) Vessel Min. working volume (L) Vessel I.D (mm) Overall Height (mm) R12-132-025 CLS-1380-R-03 3 0.5 130 260 R12-132-028 CLS-1383-R-07 7 2 160 360 - Tripod stand for unjacketed vessel
Tripod stand for unjacketed vessel Cat. No Model Vessel Capacity (L) Replacement Silicone O-Ring R12-132-031 CLS-1380-STD3 2-3 CLS-1705-150X4 R12-132-034 CLS-1382-STD5 5 CLS-1705-177X4 R12-132-037 CLS-1383-STD7 7 CLS-1705-177X4 R12-132-040 CLS-1385-STD15 15 CLS-1705-274 Jacketed glass bioreactor vessel
Cat. No Model Capacity(L) Vessel Min. working volume (L) Vessel I.D (mm) Overall Height (mm) R12-132-043 CLS-1381-01 3 0.5 130 275 R12-132-046 CLS-1382-30 5 1.0 130 275 R12-132-049 CLS-1384-01 7 2 160 375 Tripod stand for jacketed vessel
Cat. No Model Vessel Capacity
(L)Replacement Silicone O-Ring R12-132-052 CLS-1381-STD3 2-3 CLS-1705-150X4 R12-132-055 CLS-1386-STD5 5 CLS-1705-177X4 R12-132-058 CLS-1384-STD7 7 CLS-1705-177X4 Stabilizer bars
Cat. No Model Description R12-132-061 CLS-1385-SBD3 Stabilizer Bars, Set of 3, for 15L stands Headplate Assembly Stand
Cat. No Model Description R12-132-064 CLS-1380-100 Headplate Assembly Stand Agitator Assembly Cat. No Model Vessel Capacity (L) Replacement Silicone O-Ring Length of Shaft through Headplate (mm) Shaft Dia.(mm) R12-132-067 CLS-1380-05 2-5 CLS-1705-124 222 8 R12-132-070 CLS-1383-04 7 CLS-1705-124 300 8 R12-132-073 CLS-1385-05 15 CLS-1705-131 392 15 R12-132-076 CLS-1385-35 15 CLS-1705-131 390 8 - ●CLS-1385-35는 15L reactor에 사용하기 위해 Adapter Plate(CLS-1385-30)가 필요함
Rebuild Kits for Agitator Assembly
Cat. No Model Fits Agitator Shaft Size (mm) R12-132-079 CLS-1380-05PM CLS-1380-05
CLS-1383-04
CLS-1385-358 R12-132-082 CLS-1385-05PM CLS-1385-05 15 - ●Agitator assembly를 재조립 하기 위한 O-ring, Seal, Bearing Kit
Media Bottle, Clear, with Hose barb and GL-45 vented cap
Cat. No Model Vessel Capacity (mL) Tubing Size for Hose Barb R12-132-085 CLS-1423-100 100 1/4" R12-132-088 CLS-1423-250 250 1/4" R12-132-091 CLS-1423-500 500 1/4" R12-132-094 CLS-1423-1L 1000 1/4" R12-132-097 CLS-1423-2L 2000 1/4" R12-132-100 CLS-1423-5L 5000 1/4" R12-132-103 CLS-1423-10L 10,000 1/2" Vent Port Assemblies for transfer bottles
Cat. No Model Description bottle Thread Size R12-132-106 CLS-1429-10 Single Port GL-45 R12-132-109 CLS-1429-20 Two Port GL-45 R12-132-112 CLS-1429-21 Two Port Angled GL-45 - Headplate
Cat. No Model Vessel Capacity (L) Total number of ports Replacement Silicone O-Ring R12-132-115 CLS-1379-02 2 16 Total Ports
(M30 Center, 1 each G-3/4,
5 each M18, 6 each M10,
3 each M6)CLS-1705-135X4 R12-132-118 CLS-1380-03 3 18 Total Ports
(M30 Center, 1 each G-3/4,
5 each M18, 2 each M12,
6 each M10, 3 each M6)CLS-1705-135X4 R12-132-121 CLS-1382-03 5 and 7 19 Total Ports
(M30 Center, 1 each G-3/4,
5 each M18, 2 each M12,
10 each M10)CLS-1705-260 R12-132-124 CLS-1385-03 15 19 Total Ports
(69mm Center Port for Agitator,
6 each M27, 2 each M12,
10 each M10CLS-1705-373 Adapter Plate, 15L bioreactor to M30
Cat. No Model Description R12-132-127 CLS-1385-30 Adapter plate, M30 - Addition and Sampling Vessels
Cat. No Model Description R12-132-130 CLS-1437-B01 Flat Bottom Vessel Complete with 2-Port Drip tube Assembly R12-132-133 CLS-1437-B02 Flat Bottom Vessel Only R12-132-136 CLS-1429-02 2-Port Drip Tube Assembly with Open Top Cap and Gasket R12-132-139 CLS-1428-14 White Silicone Gasket Only R12-132-142 CLS-1481-20 Cap, GL-32, Blue, Open Top, PP Marine Style Impeller Blades
Cat. No Model Impeller Type Fits Reactor (L) Fits Shaft Size(mm) Impeller Dia.(mm) R12-132-145 CLS-1380-06 Vortex(Down) 2-3 8 43 R12-132-148 CLS-1380-07 Scoping(Up) 2-3 8 43 R12-132-151 CLS-1382-05 Vortex(Down) 5-7 8 59 R12-132-154 CLS-1382-06 Scoping(Up) 5-7 8 59 R12-132-157 CLS-1385-06 Vortex(Down) 15 15 76 R12-132-160 CLS-1385-07 Scoping(Up) 15 15 76 R12-132-163 CLS-1385-36 Vortex(Down) 15 8 76 R12-132-166 CLS-1385-37 Scoping(Up) 15 8 76 Rushton Style Impeller Blades
Cat. No Model Fits Reactor (L) Impeller Diameter (mm) Fits Shaft Size (mm) R12-132-169 CLS-1380-08 2-3 48 8 R12-132-172 CLS-1382-07 5-7 60 8 R12-132-175 CLS-1385-20 15 76 15 R12-132-178 CLS-1385-50 15 76 8 Triple Port Adapter, M18 and M27
Cat. No Model Thread Size Replacement Silicone O-Ring R12-132-181 CLS-1380-09 M18 CLS-1705-20X2 R12-132-184 CLS-1385-08 M27 CLS-1705-121 - Thermowell, M10
Thermowell, M10
Cat. No Model Fits Reactor (L) Immersion Length (mm) Replacement Silicone O-Ring R12-132-187 CLS-1380-11 2-5 200 CLS-1705-85X25 R12-132-190 CLS-1383-05 7 300 CLS-1705-85X25 R12-132-193 CLS-1385-10 15 370 CLS-1705-85X25 Aeration Tube with Porous Sparger, M10
Cat. No Model Fits Reactor (L) Immersion Dim "A" (mm) Replacement Silicone O-Ring R12-132-196 CLS-1379-04 2 236 48 CLS-1705-85X25 R12-132-199 CLS-1380-12 3 238 50 CLS-1705-85X25 R12-132-202 CLS-1382-08 5 238 73 CLS-1705-85X25 R12-132-205 CLS-1383-06 7 330 73 CLS-1705-85X25 R12-132-208 CLS-1385-11 15 420 93 CLS-1705-85X25 - ● 위 표에 있는 "A" 치수는 Headplate의 다른 port들에 배치를 위함임
- ● 위 표에 있는 Replacement O-Ring은 M10 연결용임
Replacement Sparger Tips
Cat. No Model Porosity(㎛) Replacement Silicone O-Ring R12-132-211 CLS-1380-14 10 CLS-1705-008 R12-132-214 CLS-1380-15 15 CLS-1705-008 Air Inlet / Outlet Adapter
Cat. No Model Thread Size Hose Connection O.D. (mm) Replacement Silicone O-Ring R12-132-217 CLS-1380-20 M10 6.35 CLS-1705-85X25 R12-132-220 CLS-1380-18 M18 12.00 CLS-1705-20X2 R12-132-223 CLS-1385-27 M27 12.00 CLS-1705-121 Sampling Tube, Adjustable, M10
Cat. No Model Fits Reactor (L) Maximum Immersion Length (mm) Replacement Silicone O-Ring R12-132-226 CLS-1380-21 2-5 232 CLS-1705-85X25 R12-132-229 CLS-1383-08 7 325 CLS-1705-85X25 R12-132-232 CLS-1385-13 15 390 CLS-1705-85X25 Blind Stoppers
Cat. No Model Size Replacement
Silicone O-RingR12-132-235 CLS-1380-22 M6 CLS-1705-010 R12-132-238 CLS-1380-23 M10 CLS-1705-85X25 R12-132-241 CLS-1380-24 M12 CLS-1705-111 R12-132-244 CLS-1380-25 M18 CLS-1705-20X2 R12-132-247 CLS-1385-14 M27 CLS-1705-121 R12-132-250 CLS-1380-26 G-3/4 CLS-1705-023 Sampling Tube, Fixed, M10 Cat. No Model Fits Reactor (L) Maximum Immersion Length (mm) Replacement Silicone O-Ring R12-132-253 CLS-1380-33 2-5 212 CLS-1705-85X25 R12-132-256 CLS-1383-14 7 315 CLS-1705-85X25 R12-132-259 CLS-1385-26 15 400 CLS-1705-85X25 Sampling Tube, Reduced Diameter Fixed, M6 Cat. No Model Fits Reactor (L) Maximum Immersion Length (mm) Replacement Silicone O-Ring R12-132-262 CLS-1380-R-33 2-5 210 CLS-1705-010 Heat Exchangers
Cat. No Model Fits Reactor (L) Exchanger Style Replacement Silicone O-Ring R12-132-265 CLS-1380-28 2-5 Cold Finger CLS-1705-20X2 R12-132-268 CLS-1382-11 5 Loop CLS-1705-85X25 R12-132-271 CLS-1383-12 7 Loop CLS-1705-85X25 R12-132-274 CLS-1385-16 15 Loop CLS-1705-85X25 Addition Pipe Cat. No Model Fits Reactor (L) Thread Size Replacement Silicone O-Ring R12-132-277 CLS-1380-31 2-7 M10 CLS-1705-85X25 R12-132-280 CLS-1380-40 3-15 M12 CLS-1705-111 R12-132-283 CLS-1380-51 2-7 M18 CLS-1705-20X2 Baffle Assembly
Cat. No Model Fits Reactor (L) Thread Size Replacement Silicone O-Ring R12-132-286 CLS-1381-04 2-3 M6 CLS-1705-010 R12-132-289 CLS-1382-10 5 M10 CLS-1705-85X25 R12-132-292 CLS-1383-11 7 M10 CLS-1705-85X25 R12-132-295 CLS-1385-17 15 M10 CLS-1705-85X25 Air aeration tube, M10
Cat. No Model Fits Reactor (L) Length of Tube Below the Headplate (mm) Replacement Silicone O-Ring R12-132-298 CLS-1379-06 2 226 CLS-1705-85X25 R12-132-301 CLS-1381-05 3-5 238 CLS-1705-85X25 R12-132-304 CLS-1384-06 7 330 CLS-1705-85X25 R12-132-307 CLS-1385-18 15 420 CLS-1705-85X25 Probe Holder, 12mm, Fixed Height
Cat. No Model Thread Size Replacement Silicone O-Ring Interior Exterior R12-132-310 CLS-1381-08 M18 CLS-1705-111 CLS-1705-20X2 R12-132-313 CLS-1381-09 G-3/4 CLS-1705-111 CLS-1705-023 R12-132-316 CLS-1385-21 M27 CLS-1705-111 CLS-1705-121 Probe Holder, 12mm, Adjustable Height Cat. No Model Thread Size Replacement Silicone O-Ring R12-132-319 CLS-1381-06 M18 CLS-1705-20X2 R12-132-322 CLS-1381-07 G-3/4 CLS-1705-023 R12-132-325 CLS-1385-19 M27 CLS-1705-121 Replacement FKM Compression Ring for 12mm Probe
Cat. No Model Description R12-132-328 1380-027 FKM Compression Ring - Probe Holder, 19mm, Adjustable height
Probe Holder, 19mm, Adjustable Height Cat. No Model Thread Size Replacement Silicone O-Ring R12-132-331 CLS-1381-10 G-3/4 CLS-1705-023 R12-132-334 CLS-1385-22 M27 CLS-1705-121 Replacement FKM Compression Ring for 19mm Probe
Cat. No Model Description R12-132-337 1381-009 FKM Compression Ring Septum Holder, M18 and M27
Cat. No Model Thread Size Replacement Silicone O-Ring R12-132-340 CLS-1380-10 M18 CLS-1705-20X2 R12-132-343 CLS-1385-09 M27 CLS-1705-121 Replacement Septa
Cat. No Model Description R12-132-346 CLS-1380-014 Silicone Rubber Septum Hamilton DO Probes to Fit Bio Reactors
Electrode System Silver Platinum Combination Polarization 670mV ± 50mV Output 40 to 80nA in Air at 25℃ Temperature 0-130℃, Sterilization to 130℃ Drift at Room Temp Under
Constant Conditions<1% per Week Stabilization Time <2 Hours Pressure 0-4 Bar Wetted Materials Stainless Steel 1.4435, EPDM and Silicone with FDA Approval Mounting PG 13.5 Thread Electrical Connector Standard 4 Pole T 82/D4 - DO Probe Standard 4 Pole T82/D4 Connector
DO Probe Standard 4 Pole T82/D4 Connector Cat. No Model Fit Reactor (L) Probe O.D. (mm) Probe Length (mm) R12-132-349 CLS-1435-D72 1-5 Liter 12 235 R12-132-352 CLS-1435-D73 7 Liter 12 320 R12-132-355 CLS-1435-D74 15 Liter 12 420 - DO Probe with VP Connector
DO Probe with VP Connector Cat. No Model Fit Reactor (L) Probe O.D. (mm) Probe Length (mm) R12-132-358 CLS-1435-D82 1-5 Liter 12 225 R12-132-361 CLS-1435-D83 7 Liter 12 325 R12-132-364 CLS-1435-D84 15 Liter 12 425 - Accessories
Accessories Cat. No Model Description R12-132-367 CLS-1435-D88 OxyFerm Membrane Kit R12-132-370 CLS-1435-D90 Cathode Assembly for OxyFerm DO Sensors R12-132-373 CLS-1435-D91 Electrolyte for OxyFerm FDA Sensors, 50mL R12-132-376 CLS-1435-D92 Protective Cap for T82 DO Sensor Autoclaving - Hamilton pH Probes Specifications
Hamilton pH Probes Specifications pH Range 0-14 Electrolyte Pressurized phermlyte Pressure Range 0-6 Bar Electrical Connector Type K8 - Standard pH Connector Head or VP Reference System HAMILTON EVEREF-F, Silver ion barrier included Temperature Range Steam Sterilizable/Autoclavable to 266℉(0 to 135℃) In-situ Sterilization Up to 100 Cycles under Standard Conditions - pH Probe Standard K8 Connector
pH Probe Standard K8 Connector Cat. No Model Fit Reactor (L) Probe O.D. (mm) Probe Length (mm) R12-132-379 CLS-1435-P72 1-5 12 225 R12-132-382 CLS-1435-P73 7 12 325 R12-132-385 CLS-1435-P74 15 12 425 - pH Probe with VP Connector
pH Probe with VP Connector Cat. No Model Fit Reactor (L) Probe O.D. (mm) Probe Length (mm) R12-132-388 CLS-1435-P77 1-5 12 225 R12-132-391 CLS-1435-P78 7 12 325 R12-132-394 CLS-1435-P79 15 12 425 - Hamilton Visiferm Optical DO Probes Specifications
Hamilton VisiFerm Optical DO probes Specifications Measuring Principle Oxygen dependent luminescence Quenching Measuring Range 4ppm to 25ppm Response Time < 30 seconds at 25℃ Autoclavable Yes Steam Sterilizable Yes (Max 140℃) Pressure Range -1 to 12 Bar Probe Diameter 12mm Connection to Process PG 13.5 Thread Electrical Connection VP8 Wetted Materials SS 1.4435, Silicone EPDM - Hamilton VisiFerm Optical DO Probes
Hamilton VisiFerm Optical DO Probes Cat. No Model Fit Reactor (L) Probe Length (mm) R12-132-397 CLS-1434-60 1-5 225 R12-132-400 CLS-1434-62 7 325 R12-132-403 CLS-1434-64 15 425 - Harvest Tube, M10 and M27
Harvest Tube, M10 and M27 Cat. No Model Vessel Capacity (L) Replacement Silicone O-Ring R12-132-406 CLS-1380-32 3 CLS-1705-85X25 R12-132-409 CLS-1382-12 5 CLS-1705-85X25 R12-132-412 CLS-1383-13 7 CLS-1705-85X25 R12-132-415 CLS-1385-23 15 CLS-1705-121 - Heating Blankets, 110V
Heating Blankets, 110V Cat. No Model Fits Reactor (L) Wattage Dimensions
W × L (in.)R12-132-418 CLS-1379-08 2 110 2.6 × 11.4 R12-132-421 CLS-1380-19 3 180 4 × 14.5 R12-132-424 CLS-1385-12 15 385 10 × 26.2 - Optional Adapter Cord
Optional Adapter Cord Cat. No Model Description R12-132-427 CG-3211-10 Optional Adapter Cord for Heating Blanket, Self-Locking - Heating Blankets, 110V with VELCRO®
Heating Blankets, 110V with VELCRO® Cat. No Model Fits Reactor (L) Wattage Dimensions
W × L (in.)R12-132-430 CLS-1380-19V 3 110 3.5 × 14 R12-132-433 CLS-1383-07V 5-7 178 5 × 18 R12-132-436 CLS-1385-12V 15 383 10 × 27 - Replacement Silicone O-Ring
Replacement Silicone O-Ring Cat. No Model I.D × Cross Section(mm) R12-132-439 CLS-1705-008 4.47 × 1.78 R12-132-442 CLS-1705-010 6.07 × 1.78 R12-132-445 CLS-1705-85X25 8.50 × 2.50 R12-132-448 CLS-1705-111 10.70 × 2.6 R12-132-451 CLS-1705-18X3 18.0 × 3.0 R12-132-454 CLS-1705-20X2 20.0 × 2.00 R12-132-457 CLS-1705-023 26.7 × 1.78 R12-132-460 CLS-1705-121 26.6 × 2.62 R12-132-463 CLS-1705-124 31.4 × 3.30 R12-132-466 CLS-1705-131 42.5 × 2.62 R12-132-469 CLS-1705-135X4 135 × 4.00 R12-132-472 CLS-1705-150X4 150 × 4.00 R12-132-475 CLS-1705-260 166 × 3.00 R12-132-478 CLS-1705-177X4 177 × 4.00 R12-132-481 CLS-1705-373 228 × 5.33 R12-132-484 CLS-1705-274 253 × 3.53 - Condensers, Glass and Stainless Steel
Condensers, Glass and Stainless Steel Cat. No Model Type Style Fits Reactor(L) Overall Lenth(mm) R12-132-487 CLS-1380-GC1 Glass Bulb-Style 2-5 150 R12-132-490 CLS-1380-GC2 Glass Bulb-Style 7 250 R12-132-493 CLS-1385-GC3 Glass Coil-Style 15 250 R12-132-496 CLS-1380-27 Stainless - 3-5 165 R12-132-499 CLS-1383-09 Stainless - 7 230 - Single-Use Bioreactor Accessory Kits
Single-use Bioreactor Accessory Kits Cat. No Model Description R12-132-502 CLS-1390-01 Complete Bioreactor Accessory Kits R12-132-505 CLS-1390-10 Media Inlet Line Assembly R12-132-508 CLS-1390-11 Sparger Line Assembly R12-132-511 CLS-1390-12 Condenser Vent Line Assembly R12-132-514 CLS-1390-13 Sample Line Assembly R12-132-517 CLS-1390-14 Overlay Gas Assembly R12-132-520 CLS-1390-15 Tri Port Assembly - Sampler, Bioreactor, Aseptic, LACH
Cat. No Model Description R12-132-523 CLS-1399-01 Sampler, Aseptic, Lach, Small R12-132-526 CLS-1399-02 Sampler, Aseptic, Lach, Large - Stirrer Specification
Stirrer Specification Fits Applikon-Style Vessels 1-7 Liters Speed Range 10-800 RPM Power 91 (in-oz.) Voltage Requirements 110 to 240 VAC, 50-60 Hz Wattage 240 Watts Max, Peak 2 Amps Operating Temperature Range 5 to 40 ℃ - Stirrers, Complete, Bioreactors
Cat. No Model Description R12-132-529 CLS-1399-100 Stirrer Motor, Controller and Cable


.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)